    Fluke 66 Infrared Thermometers

    그림확대보기
    모델FLUKE 66
    품명적외선 온도메타
    (Infrared Thermometer)
    제조사플루크 (fluke)
    ▷ 영문 카탈로그 (click-web)
    (fluke 60 Series)
    ▷ 영문 메뉴얼 (click-down)
    (Fluke63_66_68메뉴얼(영문)_1.pdf/815KB)


    This portable tools enable professionals to monitor the status of electrical motors and electrical panels, research heating and ventilation problems and diagnose car malfunctions with ease.
    제품상세정보
    장비 특징
    Fluke 66 Fluke 66
    • Laser guided sighting system for easy targeting with 1 % accuracy
    • 12-point data logging
    • Advanced optics to measure smaller targets at greater distances
    • Adjustable emissivity for more accurate temperature measurements
    • Selectable MAX, MIN, DIF and AVG functions that display values instantly with Hi/Lo Alarm
    • Expanded measurement range up to 600 °C (1100 °F)
    • Optional probe accessory available for dual contact and non-contact temperature measurements
    장비 사양 (Specification)
    Function
                                       Model
    FLUKE
    66
    Range -32 to 600 °C (-25 to 1100 °F)
    Optical resolution 30:1 at focus point
    Responce time 0.5 second (95 % of reading)
    Resolution 0.1°C
    Repeatability (% of reading) ±0.5 % or ±1 °C (±2 °F), whichever is greater
    Accuracy
    (For targets at:)
    -32 to -26 °C (-25 to -15 °F): ±3 °C (±5 °F)
    -26 to -18 °C (-15 to 0 °F): ±2.5 °C (±4 °F)
    -18 to 23 °C (-0 to 73 °F): ±2 °C (±3 °F)
    For targets above 23 °C (73 °F): ±1% of reading
    or ±1 °C (±2 °F), whichever is greater
    * assumes ambient operating temperature of 23°C (73 °F)
    Typical distance to target 5 m (15 ft.)
    Emissivity Digitally adjustable (from 0.1 to 1.0 by 0.01)
    Laser beam
    for accurate targeting
    yes
    Laser sighting (Class II) Offset single point laser point
    Spectral response 8 to 14 μm
    Backlit LCD display yes
    Use selectable °C or °F yes
    Min/max/avg/dif readings yes
    Contact capability
    (RTD Temperature Probe)
    Fluke 66/68 Option 80PR-60 (RTD Probe)
    Optional: 80PR-60 (RTD Temperature Probe)
  • Probe type: RTD (resistance temperature detector)
  • Probe element: Platinum 1 KW
  • Temperature range: -40 to 260 °C (-40 to 500 °F)
  • Accuracy: ± 1 °C (± 2 °F)
  • Jack: 3.5 mm phono type
  • Probe diameter: 4.8 mm (.187 in)
  • Probe length: 90 mm (3.5 in)
  • Cable length (extended): 1000 mm (40 in)
  • For use with the Fluke 66 and Fluke 68
  • Datalogging yes
    Hi/Lo Alarm yes
    Display hold 7 seconds
    Ambient operating temp. 0 to 50 °C (32 to 120 °F)
    Storage temperature -20 to 60 °C (-13 to 158 °F) without battery
    Relative humidity 10 to 90 % RH non-condensing, at <30 °C (86 °F) ambient
    Power 9 V alkaline or NiCd battery
    Battery Life (alkaline) 20 hours with laser and backlight on 50 %
    40 hours with laser and backlight off
    Size (Hmm x Wmm x Dmm) 200 x 160 x 55
    Weight (g) 320

    Specifications & Models are subject to change without notice.
    장비의 사양과 모델에 대한 모든 정보는 사전 예고 없이 변경이 될 수 있습니다.